Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


142 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


H07BQ-F PUR5×1.5450/750 V
H07BQ-F PUR5×10450/750 V
H07BQ-F PUR5×16450/750 V
H07BQ-F PUR5×2.5450/750 V
H07BQ-F PUR5×4450/750 V
H07BQ-F PUR5×6450/750 V
PLANOFLEX NGFLGOEU-J Control cables10×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables10×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables12×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables12×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables24×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables24×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables3×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables4×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables4×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables42×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables5×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables5×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables7×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables7×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables8×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables8×2.5300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×10300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×120300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×16300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×25300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×35300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×50300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×6300/500 V

Product details


I/O Loose Tube Optical Cables 144F (12 x 12F)

Product category: indoor cables
Type: I/O Loose Tube Optical Cables 144F (12 x 12F)
Conductor material: Optical fibre
Outer jacket material: HFFR
Nominal outer diameter: 15.5 mm
Approx. weight: 225 kg/km
Appplication: indoor/outdoor
Delivery length: 4000 m
Construction: Central Strength Member (CSM). Loose Tube containing fibres and filled with a suitable water tightness compound. Loose tubes SZ stranded around the CSM. Longitudinal Water Tightness: dry core with water swellable elements. Peripheral Strength Elements. Ripcords. Outer Sheath: black HFFR.
Standard: IEC 60794; IEC 60793; IEC 60332-1; IEC 61034; IEC 60754; ITU-T Rec. G.650; ITU-T Rec. G.652; ITU-T Rec. G.655; ITU-T Rec. G.656; ITU-T Rec. G.657
Leadfree
Minimum installation temperature: -40°C to +70°C
Application: Indoor/outdoor installation. Suitable for installation in buildings and tunnel backbones where zero halogen, flame retardance and low smoke emission are required. Those cables may be installed as well in the outside plant as inside buildings.

Data sheet