Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


CYKY7×4450/750 V
CYYpl2×1.5450/750 V
CYYpl2×2.5450/750 V
CYYpl3×1.5450/750 V
CYYpl3×2.5450/750 V
DFC - Duplex Fibre Drop Cable 2F
Dielectric Armoured Optical Cables 12F (1 x 12F)
Dielectric Armoured Optical Cables 144F (12 x 12F)
Dielectric Armoured Optical Cables 192F (16 x 12F)
Dielectric Armoured Optical Cables 24F (2 x 12F)
Dielectric Armoured Optical Cables 288F (24 x 12F)
Dielectric Armoured Optical Cables 36F (3 x 12F)
Dielectric Armoured Optical Cables 48F (4 x 12F)
Dielectric Armoured Optical Cables 60F (5 x 12F)
Dielectric Armoured Optical Cables 72F (6 x 12F)
Dielectric Armoured Optical Cables 96F (8 x 12F)
Direct Buried Glass yarn Armoured 12F (1 x 12F)
Direct Buried Glass yarn Armoured 144F (12 x 12F)
Direct Buried Glass yarn Armoured 192F (16 x 12F)
Direct Buried Glass yarn Armoured 24F (2 x 12F)
Direct Buried Glass yarn Armoured 288F (24 x 12F)
Direct Buried Glass yarn Armoured 36F (3 x 12F)
Direct Buried Glass yarn Armoured 48F (4 x 12F)
Direct Buried Glass yarn Armoured 60F (5 x 12F)
Direct Buried Glass yarn Armoured 72F (6 x 12F)
Direct Buried Glass yarn Armoured 96F (8 x 12F)
Direct buried STA 12F (1 x 12F)
Direct buried STA 144F (12 x 12F)
Direct buried STA 192F (16 x 12F)
Direct buried STA 24F (2 x 12F)

Product details


SINOTHERM (110) H07G-K 1 × 50 mm² 450/750 V

Product category: low voltage cables
Type: SINOTHERM (110) H07G-K
Rated voltage: 450/750 V
Conductor material: CU
No. of cores: 1
Cross-section: 50 mm²
Core insulation material: Gummi
Nominal outer diameter: 13.4 mm
Approx. weight: 514 kg/km
Resistant to…: heat
Appplication: Innenräumen
Construction: Conductor copper, tinned, round (R), fine stranded (F), class 5 (EN60228). Insulation heat resistant insulation based on synthetic rubber, EI3 acc. EN 50363-1.
Standard: EN 50525-2-42
Available colours: black or other
Leadfree
Minimum installation temperature: Fix inst. min -40°C, fully flexible inst. min -25°C
Application: Designed for use at ambient temperatures above 55°C. Applications include the internal wiring of luminaries, heating applications, electrical machines, switchgear and distribution boards, as well as protected, fixed installation in dry indoor areas.Core cables H07G are alowed for use in devices to a rated voltage Uo/U 600/1000V AC or Uo/U 750/1500V DC. In other respects DIN VDE 0298-300 (HD516) applies.

Data sheet