Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


SIENOPYR(120) (N)HX4GAF 0.6/1kV1×40,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×500,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×60,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×700,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×950,6/1 kV
SIENOPYR-PLUS E30 JE-H(St)H FE18012×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18012×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18016×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18016×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1802×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1802×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18020×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18020×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18024×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18024×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18032×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18032×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1804×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1804×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18040×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18040×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18052×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18052×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1808×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1808×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18080×2x0.8
SINOTHERM (110) H07G-K1×1.5450/750 V
SINOTHERM (110) H07G-K1×10450/750 V
SINOTHERM (110) H07G-K1×120450/750 V
SINOTHERM (110) H07G-K1×150450/750 V

Product details


XYMM-J 4 × 10 mm² 450/750 V

Product category: insulated and sheathed wires
Type: XYMM-J
Rated voltage: 450/750 V
Conductor material: CU
No. of cores: 4
Cross-section: 10 mm²
Core insulation material: PVC
Outer jacket material: PVC
Nominal outer diameter: 22.0 mm
Approx. weight: 770 kg/km
500 m
1000 m
Construction: Fine stranded copper wirde acc. Class 5, Insulation: cold resistant PVC, conductors stranded, outer sheath: cold resistant PVC
Standard: ÖVE K41
Available colours: yellow
Leadfree
Minimum installation temperature: -5°C
Application: In dry and humid places and outdoors, for medial and heavy mechanical stress, at low temperatures especially in the area of constructions and temporary appliances, explosive areas. Permitted temperature at cable surface: max. +70 °C for installation and handling min. -35 °C cold resistand not in operation up to -40°C

Data sheet